        Hba1c Column

        Column for HbA1C determination of Glycated Hemoglobin

        Target-Gly Series
        Packing description
         
           The matrix of target-Gly filler is polystyrene divinylbenzene (PS/DVB) or Polymethylmethacrylate(PMMA) spherical particles. Using special chemical bonding technology, ion exchange functional groups are uniformly and finely bonded on the surface of polymer hydrophilic layer. 
         
        Packing stability
         
          Because the surface modification of PS/DVB and PMMA is completely based on chemical bonding, Target-Gly ion exchange filler has excellent stability. The stationary phase can be compatible with most buffers such as ammonium acetate, phosphate, Tris, etc. At pH 6.0, Target-Gly column was operated with 20 mM phosphate buffer solution as the mobile phase, and the column efficiency hardly changed.
         
        Mobile phase compatibility
         
          Compatible with aqueous solution, mixture of water with acetonitrile, acetone or methanol, etc. Typical buffers include phosphate, Tris and acetate. 
         
        Flow rate
         
          The typical operating flow rate of chromatographic column with inner diameter of 3.0-4.6mm is 0.40-1.0ml/min.
         
        Installation and operation of  the  column
         
           Both ends of the chromatographic column are always sealed with plugs during transportation or when not in use. When connecting the chromatographic column to the chromatographic instrument system, first remove the plugs at both ends. Please note that the flow direction of the mobile phase is consistent with the direction marked on the column. Unless for special consideration, for example, when the chromatographic column needs to be connected reversely for flushing in order to remove the dirt blocked at the inlet of the chromatographic column, it is recommended that the user must follow the direction marked on the column when connecting the chromatographic column. Since the connection of chromatographic column is a part of the whole chromatographic operation process, if the sealing ferrule is too tight or improperly installed, or the sealing ferrule does not match the chromatographic column port, it may lead to the leakage of solution. Please connect the chromatographic column with the sealing ferrule according to the following steps to connect the chromatographic column to the HPLC system:
          
        (1) For the pipeline used for the first time, please put the pipeline joint and sealing card on the pipeline with an outer diameter of 1 / 16 ". The wide end of the sealing ferrule shall face the pipeline joint.
         
        (2) Tightly insert the pipeline into the interface of the chromatographic column, slide the sealing ferrule and pipeline connector forward, connect the thread of the pipeline connector with the thread of the chromatographic column port, and then tighten the pipeline connector. If the pipeline is made of polymer material, please go to step (4); If it is a metal pipeline, continue (3).
         
        (3) After firmly pressing the pipeline into the column end interface, further tighten the tightened nut with a 1 / 4 "wrench.
         
        (4) The other end of the chromatographic column is operated by the above method.
         
        Sample and mobile phase
         
        In order to avoid the blockage of chromatographic column, all samples and solvents, including buffer solution, must be filtered with 0.45um or 0.2um filter membrane before use. It is recommended to use pre- column filter (0.5m pore size) or protective column to protect the chromatographic column. Target-Gly chromatographic column can use aqueous solution or mixture of organic solvent (such as methanol, acetonitrile) and water as mobile phase. A typical mobile phase contains sodium or potassium salts of phosphoric acid, acetic acid or Tris. The mobile phase needs to be degassed before use. A simple degassing method is to ultrasonic the mobile phase under the vacuum formed by the water pump for 5 minutes.
         
        Use of chromatographic column
         
             1) The transport solvent of the new Target-Gly column is 20 mM phosphate buffer (pH 6.0). During storage and transportation, the filler may dry up. When used for the first time, it is recommended to rinse the column with a transport solvent 10-20 times the column volume to activate the column. Then, the chromatographic column can be washed with the mobile phase selected by the user for balance. The flow rate gradually rises from 0.1ml/min to the required operating conditions until the baseline is stable. If the column pressure and baseline fluctuate greatly, it may be that bubbles enter the chromatographic column. At this time, the chromatographic column can be washed at a higher flow rate for 3-10 minutes. For example, the flow rate of 4.0 * 33mm chromatographic column can be 1.5-2.0ml/min. If the type or pH of the mobile phase is quite different from the storage solvent in the chromatographic column, it is recommended to wash the chromatographic column with a new mobile phase for 10 times the column volume.
        2) In order to obtain the best separation effect and prolong the service life of the column, please try to use the mobile phase with pH in the range of 2-10.
        3) The normal operating pressure should be less than 3500psi
        4) The maximum operating temperature is 80℃. In order to prolong the service life of the column, please operate within 60℃ as far as possible.
        5) When not in use for a long time, Target-Gly column should be stored in 20 mM phosphate buffer (pH 6.0) containing 0.1% NaN3. The chromatographic column needs to be flushed with storage buffer solution at least 20 times the column volume. Then plug both ends of the chromatographic column with two detachable plugs attached to the chromatographic column to prevent the column bed from drying up.
         
        Ordering information: 
        Product  model Particle size Specifications Part No.
        Target-Gly 3um 4.6*20mm 715303-4602
        Target-Gly 5um 4.6*20mm 715305-4602
        Target-Gly 3um 4.0*33mm 715303-4003
        Target-Gly 5um 4.0*33mm 715305-4003
        Target-Gly 5um 4.0*50mm 715305-4005
         

        Next:no

        Next:no

        Back
        Contact Feedback
        Tel:06021-58830-11
        Sitemap( Google
        Copyright:MS Technologies Tel:06021-58830-0  Fax:06021-58830-11    Add:Zeppelinstr. 5, 63741 Aschaffenburg, Germany

        MS Technologies

        主站蜘蛛池模板: 欧美大片在线观看完整版| 黄色免费短视频| 成人性生交大片免费看| 亚洲欧美中文日韩二区一区| 脱顶胖熊老头同性tv| 日韩在线观看完整版电影| 免费日本黄色片| 67194线路1(点击进入)| 成人永久免费福利视频app| 免费国产成人高清视频网站| 黑人太粗太深了太硬受不了了| 天堂а√中文最新版地址| 久久一区二区明星换脸| 欧美人与物videos另类xxxxx| 免费看国产曰批40分钟| 青草午夜精品视频在线观看| 国产精品无码免费播放| 一级片在线免费看| 日韩a级毛片免费视频| 亚洲日韩亚洲另类激情文学| 日韩一区二三区国产好的精华液| 好男人社区www在线官网| 久久亚洲成a人片| 欧美亚洲综合在线| 亚洲视频欧美视频| 精品少妇一区二区三区视频| 国产呦系列免费| 一个色综合导航| 在线视频网站WWW色| 一级毛片直播亚洲| 日本人强jizzjizz| 亚洲jjzzjjzz在线播放| 老司机成人影院| 国产成人精品免费视频大全办公室 | 伊人精品视频一区二区三区| 色综合久久久久久久久五月| 国产日本韩国不卡在线视频| 57pao一国产成视频永久免费| 天堂在线www| 一区二区免费视频| 扒开双腿猛进入女人的视频|